Intel in cooler chips project

Posted on: 06/14/2023

The award is part of the COOLERCHIPS program – Cooling Operations Optimized for Leaps in Energy, Reliability, and Carbon Hyperefficiency for Information Processing Systems – supported by DOE’s Advanced Research Projects Agency-Energy (ARPA-E).

Data centers account for approximately 2% of total U.S. electricity consumption, while data center cooling can account for up to 40% of data center energy usage overall.Intel in cooler chips project

The selected projects seek to reduce the energy necessary to cool data centers and lower the operational carbon footprint associated with this critical infrastructure.


To meet the growing demands for computing capacity and performance, future data center processors are expected to require  power in excess of 2 kilowatts (kW), which would be challenging to cool with existing technologies. (Today’s most powerful chips are fast approaching 1 kW of power use.)

Intel will collaborate with academic and industry leaders to develop its innovative immersion cooling solution. Intel will oversee the research effort, provide thermal test vehicles for evaluation, and define the form factor and constraints for the next-generation processors, including hot spot locations.

Intel’s project develops ultra-low-thermal resistance, coral-shaped immersion cooling heat sinks integrated within a 3D vapor chamber cavity to support denser, higher-performance devices.

Intel’s design will address the challenge of adapting two-phase immersion cooling by optimizing 3D vapor chambers to spread the heat more effectively.

Researchers will 3D-print the novel heat sinks and test the evaporators under a range of operating conditions.

The team will pair the new vapor chamber designs with innovative boiling enhancement coatings that reduce thermal resistance by promoting high nucleation site density.

Today, fabricators apply these coatings on a flat surface, but research shows a coral-like heat sink design with internal groove-like features has the highest potential for external heat transfer coefficients with two-phase immersion cooling.

The team will use computational methods to identify the optimal design for the coral-shaped heat sinks. (For comparison, today’s heat sinks are typically made of long, parallel ribs.)

Researchers will integrate these innovations into a two-phase immersion cooling system where servers operate in a specially designed sealed tank that uses a non-conductive liquid medium.

The heat generated by servers causes the liquid to boil and generates vapor , which in turn goes through a phase change returning it to a liquid state while removing the heat (much like a home air conditioning system).

The team is aiming to improve the capability of the overall two-phase immersion cooling system from 0.025 °C/watt to less than 0.01 °C/watt, or 2.5 times (or more) improvement in efficiency.

More: Intel Dives in the Future of Cooling